Perovskite Quantum Dots Supplier - Alfa Chemistry
Banner

UV-visible Spectroscopy (UV-Vis) Services

Inquiry

Both the ultraviolet absorption spectrum and the visible absorption spectrum belong to the molecular spectrum, and they are both produced by the transition of valence electrons. The composition, content and structure of the substance can be analyzed, measured and inferred by using the ultraviolet-visible spectrum and the degree of absorption generated by the absorption of ultraviolet and visible light by the molecules or ions of the substance. Alfa Chemistry provides UV-Vis testing services for quantum dot samples to determine, analyze and infer the composition, content and structure of substances.

About Ultraviolet Spectrophotometer

The spectrophotometer is mainly composed of light source, monochromator, sample cell, detector and signal processor. The schematic diagram of its internal structure is shown in the figure below. The light source is used to provide continuous and stable photons. The monochromator is used to decompose the composite light emitted by the light source and obtain the required monochromatic light. The detector detects the intensity of the transmitted light by a photoelectric conversion element and converts it into an electrical signal.

Schematic diagram of internal structure of spectrophotometer

Ultraviolet-visible spectrophotometer has the advantages of high sensitivity, low cost, simple operation and fast analysis speed. It is often used for qualitative analysis and quantitative analysis of optical characteristics of materials.

Services

Alfa Chemistry provides professional UV-Vis testing services. Our professional and reliable team is able to provide customers with scientific and standardized test reports. Our company provides the following services:

  • Invoices, Lists and Contracts
  • Testing Reports

If you encounter problems in the service process, please feel free to communicate with us. The data we provide is in TXT format. If you need to analyze the data, please inform us in addition. We have a professional analysis team who can help you.

Sample preparation required

  • Powder Samples
  • Powder samples generally need more than 100mg, which can test absorption, reflection, and transmission.

  • Block or Film Samples
  • The required size of block or film samples>2*2cm, which can test absorption, reflection and transmission.

  • Liquid Samples
  • The liquid sample volume is 5 ml or more, the absorbance range is 3Abs, the concentration range is generally: 10 ppb-1000 ppm, and the test range is 200-800 nm. Absorption and transmission can be measured.

Advantages of our services

  • One-stop test platform, from sample preparation to test data and analysis, we include every part.
  • Reliable scientific research personnel ensure the standardization of experimental practice.
  • Short time, high efficiency.
  • The most competitive price.

What you need to know before you test

  • Determine the amount of sample required, as low volume testing may involve the incorporation of barium sulfate tablets.
  • Try to avoid unsatisfactory test results due to incorrect wavelength selection range. If you have any other questions, please contact us in time.

Testing workflow

  • Communicate with us and send samples to us
  • Put forward the test sample requirements
  • The laboratory department conducts analytical tests
  • Send data reports and analysis to customers

Testing workflow

Our customer service representatives are enthusiastic and trustworthy 24 hours a day, Monday to Friday. If you are interested in our services, please contact us.

* It should be noted that our service is only used for research, not for clinical use.

CONTACT US

Click Here to Find Us

OUR ADDRESS

  • Tel:
  • Fax:
  • Email:

For any general inquiries, please fill in the following contact form: